Journal of Cataract & Refractive Surgery
Volume 31, Issue 2 , Pages 318-323, February 2005

Clinical results of ZSAL-4 angle-supported phakic intraocular lenses in 190 myopic eyes

From the Ophthalmic Surgery Unit, Casa di Cura Rugani, Siena, Italy

Accepted 22 April 2004.

Purpose

To evaluate the efficacy and safety of angle-supported phakic intraocular lenses (IOLs) in myopia.

Setting

Private practice, Siena, Italy.

Methods

This prospective noncomparative single-surgeon interventional case series comprised 190 consecutive myopic eyes of 115 patients having implantation of a ZSAL-4 IOL (Morcher GmbH) through a 5.5 mm × 3.0 mm sclerocorneal tunnel along the steepest meridian with a surgical iridectomy. Preoperatively, the mean spherical equivalent was −14.37 diopters (D) ± 4.40 (SD) and the mean astigmatism, 1.66 ± 1.36 D.

Results

Postoperatively, the mean defocus equivalent (DEQ) was 1.55 ± 1.06 D and the mean astigmatism, 1.41 ± 1.11 D. The mean surgically induced astigmatism (vector analysis) was 1.03 ± 0.77 D (95% confidence interval [CI], 0.92 to 1.15); 146 eyes (77%) were within ±2.0 D of the DEQ, 76 eyes (40%) were within ±1.0 D, and 36 eyes (19%) were within ±0.5 D. The safety index was 1.25 and the efficacy index, 0.78. The improvement in best spectacle-corrected visual acuity (0.17) was statistically significant (95% CI, 0.14 to 0.2). Complications were intraocular pressure spike due to topical steroids, 18%; chronic iridocyclitis, 1%; explantation of unstable IOL, 1%; explantation of IOL for iridocyclitis, 0.5%; pupil ovalization, 11%; halos, 18%; and macular hemorrhage, 1%.

Conclusions

Angle-supported IOLs can effectively correct high myopia, although residual refractive errors may require secondary procedures. The main intraoperative and postoperative complications were halos, steroid response, and incorrect IOL sizing. The role of surgery in inducing macular hemorrhages should be assessed further.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Neither author has a financial or proprietary interest in any product or technique mentioned.

PII: S0886-3350(04)00669-8

doi:10.1016/j.jcrs.2004.04.051

Journal of Cataract & Refractive Surgery
Volume 31, Issue 2 , Pages 318-323, February 2005