Journal of Cataract & Refractive Surgery
Volume 31, Issue 1 , Pages 30-38, January 2005

Differences in nasal and temporal responses of the cornea after photorefractive keratectomy

From the Department of Ophthalmology, Catholic University of Rome (Serrao, M. Lombardo), Rome, and Liquid Crystal Laboratory, INFM Research Unit of Calabria, Department of Physics, University of Calabria (G. Lombardo), Rende (CS), Italy

Accepted 15 September 2004.

Purpose

To examine the differences in the biomechanical response of the peripheral regions of the cornea after photorefractive keratectomy (PRK).

Setting

Department of Ophthalmology, Catholic University of Rome, Rome, Italy.

Methods

Preoperative and 1-, 3-, 6-, and 12-month postoperative corneal topographies of 70 eyes that had PRK with the Technolas 217C excimer laser (Bausch & Lomb) were obtained. The eyes were divided into 4 groups according to the preoperative spherical equivalent refraction. Preoperative and follow-up topographic data were imported into custom software that computed the average composite corneal map and difference maps in each group to scientifically evaluate the corneal response to the surgery. The software was also used to analyze regional corneal changes after the laser ablation. Corneal peripheries up to 9.0 mm were evaluated.

Results

The preoperative corneas had a flatter nasal periphery than temporal periphery. The corneal surfaces in the right eyes and left eyes showed a mirror symmetry. Significant differences in the regional response of the cornea were observed (P<.05), with a greater increase in the curvature of the nasal periphery than in the temporal periphery.

Conclusions

To refine modeling of the cornea, the different regional anatomic features and biomechanical responses must be considered. Modifying existing ablation algorithms to compensate for the differences between nasal and temporal corneal flattening of the preoperative corneal surface and between the nasal and temporal responses may improve the postoperative corneal shape and quality of peripheral optics.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 None of the authors has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(04)01005-3

doi:10.1016/j.jcrs.2004.10.026

Journal of Cataract & Refractive Surgery
Volume 31, Issue 1 , Pages 30-38, January 2005