Journal of Cataract & Refractive Surgery
Volume 33, Issue 6 , Pages 1014-1018, June 2007

Comparative study of coaxial phacoemulsification and microincision cataract surgery:

One-year follow-up

From the Departments of Ophthalmology (Crema, Walsh, Yamane), Gama Filho University, Rio de Janeiro, and Paulista School of Medicine–UNIFESP (Crema, Nosé), São Paulo, Brazil

Accepted 5 February 2007.

Purpose

To evaluate the amount of ultrasound (US) used, best corrected visual acuity (BCVA), and corneal endothelial cell loss in bimanual microincision cataract surgery (MICS) and coaxial phacoemulsification.

Setting

Department of Ophthalmology, Universidade Gama Filho, Rio de Janeiro, Brazil.

Methods

A prospective randomized study included 30 patients (60 eyes) with bilateral cataract. All patients had coaxial phacoemulsification in 1 eye and MICS in the fellow eye. The US time and the effective US time were measured intraoperatively. The BCVA and central endothelial cell loss were evaluated in both groups over a 1-year follow-up. The results between the 2 groups were compared.

Results

The total US time was lower in the coaxial phacoemulsification group than in the MICS group; the means were 0.50 minutes ± 0.33 (SD) and 0.82 ± 0.39 minutes, respectively. The mean US power was similar between groups (mean 10.1% ± 3.76% and 10.0% ± 4.0%, respectively). The BCVA was similar between the groups from 24 hours to 1 year. The mean central corneal endothelial cell loss at 3 months was 4.66% ± 6.10% in the coaxial phacoemulsification group and 4.45% ± 5.06% in the MICS group and at 1 year, 6.00% ± 6.72% and 8.82% ± 7.39%, respectively. The only significant difference in the postoperative results between the 2 groups was central endothelial cell loss at the 1-year follow-up.

Conclusions

The US time was longer in the MICS group than in the in the coaxial phacoemulsification group, but the mean US power was similar between groups. The BCVA was also similar between groups; however, the MICS group had more central endothelial cell loss at the 1-year follow-up.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 No author has a financial or proprietary interest in any material or method mentioned.Presented in part at the XXIII Congress of the European Society of Cataract & Refractive Surgeons, Lisbon, Portugal, September 2005.

PII: S0886-3350(07)00492-0

doi:10.1016/j.jcrs.2007.02.035

Journal of Cataract & Refractive Surgery
Volume 33, Issue 6 , Pages 1014-1018, June 2007