Journal of Cataract & Refractive Surgery
Volume 33, Issue 10 , Pages 1708-1712, October 2007

Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system

  • Sinan Emre, MD

      Affiliations

    • Corresponding Author InformationCorresponding author: Dr. Sinan Emre, Inonu University School of Medicine, Turgut Ozal Medical Center, Department of Ophthalmology, TR-44280 Malatya, Turkey.
  • ,
  • Selim Doganay, MD
  • ,
  • Saim Yologlu, PhD

From the Department of Ophthalmology (Emre, Doganay) and the Department of Biostatistics (Yologlu), School of Medicine, Inonu University, Malatya, Turkey

Accepted 8 June 2007.

Purpose

To evaluate the alteration in anterior chamber parameters with the progression of keratoconus using a rotating Scheimpflug camera.

Setting

Inonu University, Turgut Ozal Medical Center, Ophthalmology Department, Malatya, Turkey.

Methods

Two hundred sixteen eyes of 123 patients diagnosed with keratoconus and 224 eyes of 112 normal subjects were evaluated with a Pentacam Scheimpflug camera (Oculus Inc.). Keratoconic eyes were divided into 3 groups according to mean keratometer (K) readings: mild (K = less than 47.0 diopters [D]), moderate (K = 47.0 to 52.0 D), and severe (K = 52.0 D or higher). The following parameters were obtained: thinnest corneal thickness (TCT), anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), and anterior chamber volume (ACV).

Results

One hundred twenty-nine eyes had mild keratoconus, 59 had moderate keratoconus, and 35 had severe keratoconus. There were no statistically significant differences between the keratoconus group and control group in age, sex, or eye distribution (P>.05). With the progression of the disease, TCT and ACD were statistically different between all groups (P<.05). There were statistically significant differences in ACA and CV measurements between the mild keratoconus and severe keratoconus groups (P<.05). Also, CV readings were significantly different between the control group and all keratoconus groups (P<.05), although there was no significant difference in ACA measurements (P>.05). Despite a progressive increase in the ACV with disease progression, the differences between groups were not statistically significant (P>.05) except between the severe keratoconus group and the control group (P<.05).

Conclusion

Anterior segment parameters of the eye showed significant alterations with the progression of keratoconus.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 No author has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(07)01068-1

doi:10.1016/j.jcrs.2007.06.020

Journal of Cataract & Refractive Surgery
Volume 33, Issue 10 , Pages 1708-1712, October 2007