Journal of Cataract & Refractive Surgery
Volume 29, Issue 5 , Pages 955-960 , May 2003

After-cataract in adults with primary posterior capsulorhexis: comparison of hydrogel and silicone intraocular lenses with round edges after 2 years

  • Michael Georgopoulos, MD

      Affiliations

    • Corresponding Author InformationReprint requests to Michael Georgopoulos, MD, Department of Ophthalmology, University of Vienna Medical School, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.
  • ,
  • Rupert Menapace, MD

      Affiliations

    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.
  • ,
  • Oliver Findl, MD

      Affiliations

    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.
  • ,
  • Vanessa Petternel, MD

      Affiliations

    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.
  • ,
  • Barbara Kiss, MD

      Affiliations

    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.
  • ,
  • Georg Rainer, MD

      Affiliations

    • Department of Ophthalmology, University of Vienna, Vienna, Austria
    • None of the authors has a financial or proprietary interest in any material or method mentioned.

,Accepted 28 August 2002.

References 

  1. Apple DJ, Solomon KD, Tetz MR, et al.  Posterior capsule opacification. Surv Ophthalmol. 1992;37:73–116
  2. Kappelhof JP, Vrensen GFJM. The pathology of after-cataract; a minireview. Acta Ophthalmol Suppl. 1992;205:13–24
  3. Rakic J-M, Galand A, Vrensen GFJM. Separation of fibres from the capsule enhances mitotic activity of human lens epithelium. Exp Eye Res. 1997;64:67–72
  4. Gimbel HV, Neuhann T. Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990;16:31–37
  5. Castaneda VE, Legler UFC, Tsai JC, et al.  Posterior continuous curvilinear capsulorhexis; an experimental study with clinical applications. Ophthalmology. 1992;99:45–50
  6. Gimbel HV, DeBroff BM. Posterior capsulorhexis with optic capture (maintaining a clear visual axis after pediatric cataract surgery). J Cataract Refract Surg. 1994;20:658–664
  7. Koch DD, Kohnen T. Retrospective comparison of techniques to prevent secondary cataract formation after posterior chamber intraocular lens implantation in infants and children. J Cataract Refract Surg. 1997;23:657–663
  8. Ellis FJ. Management of pediatric cataract and lens opacities. Curr Opin Ophthalmol. 2002;13:33–37
  9. Galand A, van Cauwenberge F, Moosavi J. Posterior capsulorhexis in adult eyes with intact and clear capsules. J Cataract Refract Surg. 1996;22:458–461
  10. Tassignon M-J, De Groot V, Smets RME, et al.  Secondary closure of posterior continuous curvilinear capsulorhexis. J Cataract Refract Surg. 1996;22:1200–1205
  11. Tassignon MJ, De Groot V, Vervecken F, Van Tenten Y. Secondary closure of posterior continuous curvilinear capsulorhexis in normal eyes and eyes at risk for postoperative inflammation. J Cataract Refract Surg. 1998;24:1333–1338
  12. Menapace R, Findl O, Georgopoulos M, et al.  The capsular tension ring (designs, applications, and techniques). J Cataract Refract Surg. 2000;26:898–912
  13. Georgopoulos M, Menapace R, Findl O, et al.  Primäre posteriore Kapsulorhexis (Einfluβ der retrokapsulären Viskoelastikumgabe auf den Augeninnendruckverlauf). In:  Duncker F,  Ohrloff C,  Wilhelm F editor. 12. Kongreβ der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation und refraktive Chirurgie, 1998. Berlin: Springer-Verlag; 1999;p. 59–63
  14. Pande MV, Ursell PG, Spalton DJ, et al.  High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery. J Cataract Refract Surg. 1997;23:1521–1527
  15. Buehl W, Findl O, Menapace R, et al.  Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification. J Cataract Refract Surg. 2002;28:265–270
  16. Findl O, Buehl W, Menapace R, et al. Comparison of 4 methods for quantifying posterior capsule opacification. J Cataract Refract Surg 2003; 29:106–111
  17. Kim M-J, Lee H-Y, Joo C-K. Posterior capsule opacification in eyes with a silicone or poly(methyl methacrylate) intraocular lens. J Cataract Refract Surg. 1999;25:251–255
  18. Apple DJ. Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity. Trans Am Ophthalmol Soc. 2000;98:257–283
  19. Abela-Formanek C, Amon M, Schild G, et al.  Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg. 2002;28:50–61
  20. Tetz MR, Auffarth GU, Sperker M, et al.  Photographic image analysis system of posterior capsule opacification. J Cataract Refract Surg. 1997;23:1515–1520
  21. Friedman DS, Duncan DD, Munoz B, et al.  Digital image capture and automated analysis of posterior capsular opacification. Invest Ophthalmol Vis Sci. 1999;40:1715–1726
  22. Georgopoulos M, Menapace R, Findl O, et al.  Posterior continuous curvilinear capsulorhexis with hydrogel and silicone intraocular lens implantation (development of capsulorhexis size and capsule opacification). J Cataract Refract Surg. 2001;27:825–832

PII: S0886-3350(02)01814-X

doi: 10.1016/S0886-3350(02)01814-X

Journal of Cataract & Refractive Surgery
Volume 29, Issue 5 , Pages 955-960 , May 2003