Journal of Cataract & Refractive Surgery
Volume 30, Issue 6 , Pages 1326-1334, June 2004

Resulting refraction after same-day bilateral phacoemulsification

  • Björn Johansson, MD

      Affiliations

    • Corresponding Author InformationReprint requests to Björn Johansson, MD, Department of Ophthalmology, Linköping University Hospital, SE 581 85 Linköping, Sweden.

Department of Ophthalmology, Linköping University Hospital, Linköping, Sweden

Accepted 29 October 2003.

Abstract 

Purpose: To study the refraction achieved after same-day bilateral cataract surgery, particularly with regard to anisometropia and the incidence of patient dissatisfaction caused by this complication.

Setting: Department of Ophthalmology, University Hospital of Linköping, Sweden.

Methods: This was a retrospective study of 165 consecutive patients who had bilateral cataract surgery on the same day. Parameters examined were preoperative and postoperative visual acuity and refraction (spherical equivalent), preoperative keratometry and axial lengths, planned postoperative refraction, difference between planned and achieved refraction, anisometropia, and recorded evidence of patient dissatisfaction resulting from refraction or binocularity problems.

Results: Postoperative refraction was within ±0.5 diopter (D) from target in 43%, ±1 D from target in 71%, and ±2 D from target in 95% of eyes. Anisometropia was ≤0.5 D in 48% of patients and ≤1 D in 82% of patients. Two patients (1.2%) had anisometropia >2 D. No patient returned with complaints caused by postoperative refraction.

Conclusions: Although deviation from planned postoperative refraction occurred in several cases, no patient reported binocularity problems in the 1% of cases with significant anisometropia. Risk for deviation from planned refraction does not appear to be a contraindication to same-day bilateral phacoemulsification in patients without known risk factors.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The author has no proprietary or financial interest in any product or method mentioned.

PII: S0886-3350(04)00002-1

doi:10.1016/j.jcrs.2003.10.036

Journal of Cataract & Refractive Surgery
Volume 30, Issue 6 , Pages 1326-1334, June 2004