Journal of Cataract & Refractive Surgery
Volume 30, Issue 7 , Pages 1454-1460, July 2004

Correction of presbyopia with refractive multifocal phakic intraocular lenses

From Monticelli Clinic, Marseilles, France

Accepted 5 December 2003.

Abstract 

Purpose: To evaluate the efficacy of and specify the conditions required for implantation of an anterior chamber multifocal phakic intraocular lens (IOL) to correct presbyopia.

Setting: Monticelli Clinic, Marseilles, France.

Method: Fifty-five eyes of 33 patients (21 women, 12 men) had implantation of a foldable anterior chamber multifocal phakic IOL. The initial refraction was between −5.00 diopters (D) and +5.00 D. The IOL had an addition of +2.50 D. An uncorrected distance acuity of 0.6 or better (decimal scale) and an uncorrected near acuity (Parinaud scale) of 3 or better (Parinaud 2 ≅ Jaeger 1) was considered a successful postoperative result.

Results: The mean follow-up was 42.6 weeks ± 18 (SD). Postoperatively, the mean refraction was −0.12 ± 0.51 D, the mean decimal uncorrected distance acuity was 0.78 ± 0.20, and the mean Parinaud uncorrected near acuity was 2.3 ± 0.6. Eighty-four percent of eyes achieved an uncorrected distance acuity of 0.60 or better and an uncorrected near acuity of Parinaud 3 or better. The IOL was explanted in 4 eyes for different, but essentially optical, reasons. No significant anatomic complications were observed.

Conclusions: Implantation of an anterior chamber multifocal phakic IOL to correct presbyopia was effective and gave good predictability. The procedure is reversible in cases of patient intolerance to the IOL, unwanted optical phenomena, or complications. Strict inclusion criteria should be used for patient selection.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Dr. Baı̈koff has a financial interest. None of the other authors has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(04)00075-6

doi:10.1016/j.jcrs.2003.12.051

Journal of Cataract & Refractive Surgery
Volume 30, Issue 7 , Pages 1454-1460, July 2004