Journal of Cataract & Refractive Surgery
Volume 30, Issue 11 , Pages 2359-2365 , November 2004

Corneal edema and intraocular pressure after cataract surgery: Randomized comparison of Healon5 and Amvisc Plus

  • Carlos L. Moser, MD

      Affiliations

    • Corresponding Author InformationReprint requests to Carlos L. Moser, MD, Ophthalmology Department, Hospital General de L'Hospitalet, Consorci Sanitari Integral, Avenida Josep Molins 29-41, 08906 L'Hospitalet de Llobregat, Barcelona, Spain.
    • Ophthalmology Department, Hospital General de L'Hospitalet, Consorci Sanitari Integral, L'Hospitalet de Llobregat, Barcelona, Spain
  • ,
  • Montserrat Martin-Baranera, MD,PhD

      Affiliations

    • Unit of Clinical Epidemiology, Hospital General de L'Hospitalet, Consorci Sanitari Integral, L'Hospitalet de Llobregat, Barcelona, Spain
  • ,
  • Magela Garat, MD

      Affiliations

    • Ophthalmology Department, Hospital General de L'Hospitalet, Consorci Sanitari Integral, L'Hospitalet de Llobregat, Barcelona, Spain
  • ,
  • Pedro Vı́ctor de Miguel, MD

      Affiliations

    • Ophthalmology Department, Hospital General de L'Hospitalet, Consorci Sanitari Integral, L'Hospitalet de Llobregat, Barcelona, Spain
  • ,
  • Marc Rubio, MD

      Affiliations

    • Ophthalmology Department, Hospital General de L'Hospitalet, Consorci Sanitari Integral, L'Hospitalet de Llobregat, Barcelona, Spain

,Accepted 9 March 2004.

References 

  1. Miyata K, Maruoka S, Nakahara M, et al.  Corneal endothelial cell protection during phacoemulsification:low- versus high-molecular-weight sodium hyaluronate. J Cataract Refract Surg. 2002;28:1557–1560
  2. Hayashi K, Nakao F, Hayashi F. Corneal endothelial cell loss following phacoemulsification using the small-port phaco. Ophthalmic Surg. 1994;25:510–513
  3. Behndig A, Lundberg B. Transient corneal edema after phacoemulsification (comparison of 3 viscoelastic regimens). J Cataract Refract Surg. 2002;28:1551–1556
  4. Miller KM, Colvard DM. Randomized clinical comparison of Healon GV and Viscoat. J Cataract Refract Surg. 1999;25:1630–1636
  5. Holzer MP, Tetz MR, Auffarth GU, et al.  Effect of Healon5 and 4 other viscoelastic substances on intraocular pressure and endothelium after cataract surgery. J Cataract Refract Surg. 2001;27:213–218
  6. Davis EA, Lindstrom RL. Corneal thickness and visual acuity after phacoemulsification with 3 viscoelastic materials. J Cataract Refract Surg. 2000;26:1505–1509
  7. McDermott ML, Hazlett LD, Barrett RP, Lambert RJ. Viscoelastic adherence to corneal endothelium following phacoemulsification. J Cataract Refract Surg. 1998;24:678–683
  8. Price N, Jacobs P, Cheng H. Rate of endothelial cell loss in the early postoperative period after cataract surgery. Br J Ophthalmol. 1982;66:709–713
  9. Lavery KT, McDermott ML, Ernest PH, et al.  Endothelial cell loss after 4 mm cataract surgery. J Cataract Refract Surg. 1995;21:305–308
  10. Olsen T. The endothelial cell density after cataract surgery in young patients. Acta Ophthalmol. 1981;59:242–246
  11. Jacob JSH. Corneal thickness changes following cataract surgery (effect of lens implantation and sodium hyaluronate). Br J Ophthalmol. 1985;69:567–571
  12. Arshinoff SA, Albiani DA, Taylor-Laporte J. Intraocular pressure after bilateral cataract surgery using Healon, Healon5, and Healon GV. J Cataract Refract Surg. 2002;28:617–625
  13. Henry JC, Olander K. Comparison of the effect of four viscoelastic agents on early postoperative intraocular pressure. J Cataract Refract Surg. 1996;22:960–966
  14. Berson FG, Patterson MM, Epstein DL. Obstruction of aqueous outflow by sodium hyaluronate in enucleated human eyes. Am J Ophthalmol. 1983;95:668–672
  15. Arshinoff SA. Dispersive and cohesive viscoelastic materials in phacoemulsification. Ophthalmic Pract. 1995;13:98–104
  16. Glasser DB, Osborn DC, Nordeen JF, Min Y-I. Endothelial protection and viscoelastic retention during phacoemulsification and intraocular lens implantation. Arch Ophthalmol. 1991;109:1438–1440
  17. Maár N, Graebe A, Schild G, et al.  Influence of viscoelastic substances used in cataract surgery on corneal metabolism and endothelial morphology (comparison of Healon and Viscoat). J Cataract Refract Surg. 2001;27:1756–1761
  18. Tetz MR, Holzer MP. Two-compartment technique to remove ophthalmic viscosurgical devices. J Cataract Refract Surg. 2000;26:641–643
  19. Zetterström C, Wejde G, Taube M. Healon5 (comparison of 2 removal techniques). J Cataract Refract Surg. 2002;28:1561–1564
  20. Kasetti SR, Desai SP, Sivakumar S, Sunderraj P. Preventing intraocular pressure increase after phacoemulsification and the role of perioperative apraclonidine. J Cataract Refract Surg. 2002;28:2177–2180
  21. Kohnen T, von Ehr M, Schütt E, Koch DD. Evaluation of intraocular pressure with Healon and Healon GV in sutureless cataract surgery with foldable lens implantation. J Cataract Refract Surg. 1996;22:227–237
  22. Holladay JT, Prager TC. Mean visual acuity. Am J Ophthalmol. 1991;111:372–374 [letter]
  23. Dick HB, Augustin AJ, Pfeiffer N. Osmolality of various viscoelastic substances (comparative study). J Cataract Refract Surg. 2000;26:1242–1246
  24. Holmén JB, Lundgren B. Scheimpflug photography study of ophthalmic viscosurgical devices during simulated cataract surgery. J Cataract Refract Surg. 2003;29:568–574
  25. Zetterstrom C, Laurell C-G. Comparison of endothelial cell loss and phacoemulsification energy during endocapsular phacoemulsification surgery. J Cataract Refract Surg. 1995;21:55–58
  26. Hayashi K, Hayashi H, Nakao F, Hayashi F. Risk factors for corneal endothelial injury during phacoemulsification. J Cataract Refract Surg. 1996;22:1079–1084
  27. Vajpayee RB, Bansal A, Sharma N, et al.  Phacoemulsification of white hypermature cataract. J Cataract Refract Surg. 1999;25:1157–1160

 None of the authors has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(04)00539-5

doi: 10.1016/j.jcrs.2004.05.004

Journal of Cataract & Refractive Surgery
Volume 30, Issue 11 , Pages 2359-2365 , November 2004