« Previous
Next »
Journal of Cataract & Refractive Surgery
Volume 31, Issue 7
, Pages 1338-1344
, July 2005
Clinical application of the lens haptic plane concept with transformed axial lengths
References
- . The lens haptic plane (LHP) a fixed reference for IOL implant power calculation. Eur J Implant Refract Surg. 1995;7:202–209
- . Prediction of intraocular lens power using the lens haptic plane concept. J Cataract Refract Surg. 1997;23:254–259
- . Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power. J Cataract Refract Surg. 2004;30:1000–1005
- . Comparison of 2 A-scans. J Cataract Refract Surg. 2003;29:95–99
- . Contribution of the cornea and internal surfaces to the change of ocular aberrations with age. J Opt Soc Am A Opt Image Sci Vis. 2002;19:137–143
- . Ocular higher-order aberrations in individuals screened for refractive surgery. J Cataract Refract Surg. 2003;29:1896–1903
- Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted. Arch Ophthalmol. 2002;120:1143–1151
- . Reduction of trend errors in power calculation by linear transformation of measured axial lengths. J Cataract Refract Surg. 2003;29:100–105
- . Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238:765–773
- . Multicenter biometry study of 1 pair of eyes. J Cataract Refract Surg. 2001;27:1656–1661
- . [Dimension comparison of axial length and corneal curvature between Japanese and Caucasians]. (Japanese) Jpn Rev Clin Ophthalmol. 1986;80:2167–2170
- . Lens thickness in Western Nigeria; a comparative ultrasonic study in Negros and Danes. Acta Ophthalmol. 1985;63:274–276
- . Clinical results using the Holladay 2 intraocular lens power formula. J Cataract Refract Surg. 2000;26:1233–1237
- . Anterior chamber depth measurement: A-scan versus optical methods. J Cataract Refract Surg. 2002;28:243–247
- Bissman W. Optical ACD measurement with the Zeiss IOLMaster. Available at: http://www.augenklinik.uni-wuerzburg.de/eulib/texte/czjacd-e.htm (site managed by Haigis W). Accessed.
- A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17–24
- . The Hoffer Q formula: A comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19:700–712errata 1994; 20:677
- . Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990;16:333–340correction, 528
- . Relationship of the actual thick intraocular lens optic to the thin lens equivalent. Am J Ophthalmol. 1998;126:339–347
- . Biometry of the posterior lens capsule: a new method to predict pseudophakic anterior chamber depth. J Cataract Refract Surg. 1990;16:202–206
- Posterior capsule opacification. Surv Ophthalmol. 1992;37:73–116
- Postoperative change in effective lens posistion of a 3-piece acrylic intraocular lens. J Cataract Refract Surg. 2003;29:1974–1979
Presented in part at the ASCRS Symposium on Cataract, IOL and Refractive Surgery, Boston, Massachusctts, USA, May 2000.Sverker Norrby is an employee of AMO (formerly Pharmacia), and Eva Lydahl was a consultant to Pharmacia at the time of this study. No other author has a financial or proprietary interest in any material or method mentioned.
PII: S0886-3350(05)00150-1
doi: 10.1016/j.jcrs.2004.12.061
© 2005 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Cataract & Refractive Surgery
Volume 31, Issue 7
, Pages 1338-1344
, July 2005