Clinical comparison of 6 aberrometers Part 2: Statistical comparison in a test group
References
- . Comparison of the eye's wave-front aberration measured psychophysically and with the Shack-Hartmann wave-front sensor. J Opt Soc Am A Opt Image Sci Vis. 1998;15:2457–2465
- . Laser ray tracing versus the Hartmann-Shack sensor for measuring optical aberrations in the human eye. J Opt Soc Am A Opt Image Sci Vis. 2000;17:974–985
- . Comparing laser ray tracing, the spatially resolved refractometer, and the Hartmann-Shack sensor to measure the ocular wave aberration. Optom Vis Sci. 2001;78:152–156
- Comparison of monochromatic ocular aberrations measured with an objective cross-cylinder aberroscope and a Shack-Hartmann aberrometer. Optom Vis Sci. 2003;80:15–25
- . Comparing wavefront devices. In: Krueger RR, Applegate RA, MacRae SM editor. Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 161–168
- . Evaluation of refractive error measurements of the WaveScanWavefront System and the Tracey wavefront aberrometer. J Cataract Refract Surg. 2003;29:970–979
- . Slit Skiascopic-guided ablation using the Nidek Laser. J Ref Surg. Sept/Oct 2000;16:S576–S580
- . Objective measurement of wavefront aberrations of the human eye with the use of a Hartmann-Shack sensor wave-front sensor. J Opt Soc Am A. 1994;11:1949–1957
- . Measurement of eye aberrations in a speckle field. Quantum Electronics. 2001;12:1108–1112
- Principles of Tscherning aberrometry. J Refract Surg. 2000;16:S570–S571
- . Optimizing the Shack-Hartmann Sensor. In: Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 131–136
- Retinal imaging aberrometry: principles and application of the Tscherning aberrometer. In: Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 137–144
- Retinal imaging aberrometry: principles and applications of the tracey (ray tracing) aberrometer. In: Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 145–148
- . Retinoscopic double pass aberrometry: principles and application of the NIDEK OPD-Scan. In: Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 149–154
- . Variation in ocular aberrations over seconds, minutes, hours, days, months, and years. In: Krueger RR, Applegate RA, MacRae SM editor. Wavefront Customized Visual Correction; The Quest for Super Vision II. Thorofare, NJ: Slack; 2004;p. 109–113
- . Standards for reporting the optical aberrations of eyes. Trends in Optics and Photonics. 2000;35:232–244
- . Are all aberrations equal?. J Refract Surg. 2002;18:S556–S562
- . Statistical Power Analysis for Behavioral Sciences. 2d ed.. Hillsdale, NJ: L. Erlbaum; 1988;
Sponsored by an ESCRS grant (2002) and a 2002 grant of the Belgian Fund for Research in Ophthalmology (2002).No author has a financial or proprietary interest in any material or method mentioned.The authors thank the companies—Nidek, Bausch & Lomb, Zeiss, WaveLight, and Tracey—and their Belgian representatives for temporarily providing their aberrometers for our study. The authors thank Michael Mrochen for the lending of the MultiSpot aberrometer and Andrei Larichev and Nikita Irochnikov for providing the necessary technical assistance.
PII: S0886-3350(05)00152-5
doi: 10.1016/j.jcrs.2004.11.052
© 2006 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Cataract & Refractive Surgery
Volume 32, Issue 1
, Pages 33-44
, January 2006