Journal of Cataract & Refractive Surgery
Volume 32, Issue 3 , Pages 419-424 , March 2006

Prediction of the effective postoperative (intraocular lens) anterior chamber depth

  • Thomas Olsen, MD

      Affiliations

    • Corresponding Author InformationReprint requests to Thomas Olsen, MD, University Eye Clinic, Aarhus Kommunehospital, DK-8000 Aarhus C, Denmark.

,Accepted 15 August 2005.

References 

  1. Colenbrander MC. Calculation of the power of an iris clip lens for distant vision. Br J Ophthalmol. 1973;57:735–740
  2. Binkhorst RD. The optical design of intraocular lens implants. Ophthalmic Surg. 1975;6(3):17–31
  3. Fyodorov SN, Galin MA, Linksz A. Calculation of the optical power of intraocular lenses. Invest Ophthalmol. 1975;14:625–628
  4. Sanders DR, Kraff M. Improvement of intraocular lens power calculation using empirical data. Am Intra-ocular Implant Soc J. 1980;6:263–267erratum 1981; 7:82
  5. Holladay JT, Prager TC, Chandler TY, et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17–24
  6. Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II™ formula and other second generation formulas. J Cataract Refract Surg. 1988;14:136–141
  7. Haigis W. The Haigis formula. In:  Shammas HJ editors. Intraocular Lens Power Calculations. Thorofare, NJ: Slack; 2004;p. 41–57
  8. Olsen T, Olesen H, Thim K, Corydon L. Prediction of postoperative intraocular lens chamber depth. J Cataract Refract Surg. 1990;16:587–590
  9. Olsen T, Olesen H, Thim K, Corydon L. Prediction of pseudophakic anterior chamber depth with the newer IOL calculation formulas. J Cataract Refract Surg. 1992;18:280–285
  10. Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg. 1995;21:313–319
  11. Olsen T. The Olsen formula. In:  Shammas HJ editors. Intraocular Lens Power Calculations. Thorofare, NJ: Slack; 2004;p. 27–38
  12. Sanders DR, Retzlaff JA, Kraff MC, et al. Comparison of the SRK/T formula and other theoretical and regression formulas. J Cataract Refract Surg. 1990;16:341–346
  13. Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18:125–129
  14. Olsen T, Thorwest M. Calibration of axial length measurements with the Zeiss IOLMaster. J Cataract Refract Surg. 2005;31:1345–1350
  15. Eleftheriadis H. IOLMaster biometry: refractive results of 100 consecutive cases. Br J Ophthalmol. 2003;87:960–963
  16. Findl O, Kriechbaum K, Sacu S, et al. Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery. J Cataract Refract Surg. 2003;29:1950–1955
  17. Kielhorn I, Rajan MS, Tesha PM, et al. Clinical assessment of the Zeiss IOLMaster. J Cataract Refract Surg. 2003;29:518–522
  18. Connors R, Boseman P, Olson RJ. Accuracy and reproducibility of biometry using partial coherence interferometry. J Cataract Refract Surg. 2002;28:235–238
  19. Jansson F, Kock E. Determination of the velocity of ultrasound in the human lens and vitreous. Acta Ophthalmol. 1962;40:420–433
  20. Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg. 1995;21:313–319
  21. Binkhorst RD. Intraocular Lens Power Calculation Manual. A Guide to the Author's TI CC-40 Programs. 3rd ed. New York, NY: Richard D Binkhorst; 1984;
  22. Olsen T. Prediction of intraocular lens position after cataract extraction. J Cataract Refract Surg. 1986;12:376–379
  23. Olsen T. Theoretical, computer-assisted prediction versus SRK prediction of postoperative refraction after intraocular lens implantation. J Cataract Refract Surg. 1987;13:146–150
  24. Olsen T, Thim K, Corydon L. Theoretical versus SRK I and SRK II calculation of intraocular lens power. J Cataract Refract Surg. 1990;16:217–225
  25. Haigis W, Waller W, Duzanec Z, Voeske W. Postoperative biometry and keratometry after posterior chamber lens implantation. Eur J Implant Refract Surg. 1990;2:191–202
  26. Lepper RD, Trier HG. Refraction after intraocular lens implantation: results with a computerized system for ultrasonic biometry and for implant lens power calculation. Doc Ophthalmol Proc Ser. 1984;38:243–248
  27. Hoffer KJ. Biometry of 7,500 cataractous eyes. Am J Ophthalmol. 1980;90:360–368correction 890
  28. Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238:765–773
  29. Olsen T, Thim K, Corydon L. Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg. 1991;17:187–193
  30. Olsen T, Gimbel H. Phacoemulsification, capsulorhexis, and intraocular lens power prediction accuracy. J Cataract Refract Surg. 1993;19:695–699
  31. Norrby NES, Koranyi G. Prediction of intraocular lens power using the lens haptic plane concept. J Cataract Refract Surg. 1997;23:254–259
  32. Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19:700–712
  33. Holladay JT, Prager TC, Chandler TY, et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17–24
  34. Olsen T. On the calculation of power from curvature of the cornea. Br J Ophthalmol. 1986;70:152–154

 Supported by a grant from the Danish Eye Health Society.The author has no financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(05)01192-2

doi: 10.1016/j.jcrs.2005.12.139

Journal of Cataract & Refractive Surgery
Volume 32, Issue 3 , Pages 419-424 , March 2006