Use of the Unfolder Silver/Sapphire system to inject capsular tension ring during phacoemulsification in cases with subluxated cataract
Accepted 28 January 2006.
Capsular tension rings (CTRs) have proved to be useful devices in cataract surgery in cases of zonular weakness and dialysis. They can be inserted with the help of forceps or commercially available injection systems. We describe use of the Unfolder Silver/Sapphire Series implantation system (Advanced Medical Optics, Inc.) to inject a CTR into the capsular bag during phacoemulsification in cases with subluxated cataract. The implantation system used for CTR insertion can subsequently be used for implantation of a foldable intraocular lens.
From the R.P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
Corresponding author: Harinder Singh Sethi, MD, DNB, FRCS, Room 485, R.P. Centre for Ophthalmic Sciences, AIIMS, New Delhi 110029, India.
No author has a financial or proprietary interest in any product mentioned.