Journal of Cataract & Refractive Surgery
Volume 33, Issue 9 , Pages 1522-1529 , September 2007

Effects of misalignment during corneal topography

,Accepted 7 May 2007.

References 

  1. Abbas UL, Hersh PS. Early corneal topography patterns after excimer laser photorefractive keratectomy for myopia. J Refract Surg. 1999;15:124–131
  2. Auffarth GU, Wang L, Völcker HE. Keratoconus evaluation using the Orbscan Topography System. J Cataract Refract Surg. 2000;26:222–228
  3. Barker NH, Couper TA, Taylor HR. Changes in corneal topography after laser in situ keratomileusis for myopia. J Refract Surg. 1999;15:46–52
  4. Demirbas NH, Pflugfelder SC. Topographic pattern and apex location of keratoconus on elevation topography maps. Cornea. 1998;17:476–484
  5. Kampmeier J, Tanzer DJ, Er H, et al. Significance of corneal topography in predicting patient complaints after photorefractive keratectomy. J Cataract Refract Surg. 1999;25:492–499
  6. Santo RM, Bechara SJ, Kara-José N. Corneal topography in asymptomatic family members of a patient with pellucid marginal degeneration. Am J Ophthalmol. 1999;127:205–207
  7. Spadea L, Bianco G, Masini MC, Balestrazzi E. Videokeratographic changes after laser in situ keratomileusis to correct high myopia. J Cataract Refract Surg. 1999;25:1589–1595
  8. Hubbe RE, Foulks GN. The effect of poor fixation on computer-assisted topographic corneal analysis. Pseudokeratoconus. Ophthalmology. 1994;101:1745–1748
  9. Wang JY, Rice DA, Klyce SD. Analysis of the effects of astigmatism and misalignment on corneal surface reconstruction from photokeratoscopic data. Refract Corneal Surg. 1991;7:129–140
  10. Spielmann A. Les Strabismes; de l'Analyse Clinique à la Synthèse Chirurgicale. 2nd edition. Paris, France: Masson; 1991;chapter 2
  11. Rabinowitz YS. Videokeratographic indices to aid in screening for keratoconus. J Refract Surg. 1995;11:371–379
  12. Gatinel D, Haouat M, Hoang-Xuan T. Étude des paramètres permettant la description mathématique de l'asphéricite cornéenne. [A review of mathematical descriptors of corneal asphericity.]. J Fr Ophtalmol. 2002;25:81–90
  13. Benjamini Y, Hochberg Y. Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Statist Soc B. 1995;57:289–300
  14. Silverman CM. Misalignment of videokeratoscope produces pseudo-keratoconus suspect. [letter] J Refract Corneal Surg. 1994;10:468
  15. Mandell RB, Chiang CSA, Yee L. Asymmetric corneal toricity and pseudokeratoconus in videokeratography. J Am Optom Assoc. 1996;67:540–547
  16. Accardo PA, Pensiero S. Neural network-based system for early keratoconus detection from corneal topography. J Biomed Inform. 2002;35:151–159
  17. Bowman CB, Thompson KP, Stulting RD. Refractive keratotomy in keratoconus suspects. J Refract Surg. 1995;11:202–206
  18. Dingeldein SA, Klyce SD. The topography of normal corneas. Arch Ophthalmol. 1989;107:512–518
  19. Roberts C. Analysis of the inherent error of the TMS-1 Topographic Modeling System in mapping a radially aspheric surface. Cornea. 1995;14:258–265
  20. Klein SA, Mandell RB. Axial and instantaneous power conversion in corneal topography. Invest Ophthalmol Vis Sci. 1995;36:2155–2159
  21. Ousley PJ, Terry MA. Objective screening methods for prior refractive surgery in donor tissue. Cornea. 2002;21:181–188
  22. Terry MA, Ousley PJ. New screening methods for donor eye-bank eyes. Cornea. 1999;18:430–436
  23. Terry MA, Ousley PJ, Rich LF, Wilson DJ. Evaluation of prior photorefractive keratectomy in donor tissue. Cornea. 1999;18:353–358

 No author has a financial or proprietary interest in any material or method mentioned.Supported by the FRSQ Research in Vision Network, Montreal, Quebec, and the Canadian Institutes for Health Research, Ottawa, Ontario, Canada; the CIHR Institute of Neurosciences, Mental Health and Addiction, the Léon-Frédéricq Foundation, University of Liège, Belgium; and a mandate for clinical research, CHU Liège, Belgium; Le Fonds Besner-Valois and Le Fonds de recherche en ophtalmologie de l'Université de Montréal, University of Montreal, Montreal, Quebec, Canada.Presented at the World Cornea Congress V and ASCRS Symposium on Cataract, IOL and Refractive Surgery, Washington, DC, USA, April 2005.

PII: S0886-3350(07)01067-X

doi: 10.1016/j.jcrs.2007.05.029

Journal of Cataract & Refractive Surgery
Volume 33, Issue 9 , Pages 1522-1529 , September 2007