Journal of Cataract & Refractive Surgery
Volume 33, Issue 12 , Pages 2049-2053 , December 2007

Comparison of corneal flap thickness between primary eyes and fellow eyes using the Zyoptix XP microkeratome

  • Thomas Ho, MRCOphth
  • ,
  • Arthur C.K. Cheng, MCRS, FCOphth(HK)

      Affiliations

    • Corresponding Author InformationCorresponding author: Arthur Cheng, MCRS, FCOphth(HK), Department of Ophthalmology, Hong Kong Sanatorium and Hospital, 5/F, Central Block, 2 Village Road, Happy Valley, Hong Kong, People's Republic of China.
  • ,
  • Silvania Lau
  • ,
  • Dennis S.C. Lam, FRCS, FRCOphth

,Accepted 28 July 2007.

References 

  1. Binder PS. Ectasia after laser in situ keratomileusis. J Cataract Refract Surg. 2003;29:2419–2429
  2. Gimbel HV, Basti S, Kaye GB, Ferensowicz M. Experiences during the learning curve of laser in situ keratomileusis. J Cataract Refract Surg. 1996;22:542–550
  3. El-Maghraby A, Salah T, Waring GO, et al. Randomized bilateral comparison of excimer laser in situ keratomileusis and photorefractive keratectomy for 2.50 to 8.00 diopters of myopia. Ophthalmology. 1999;106:447–457
  4. Pérez-Santonja JJ, Bellot J, Claramonte P, et al. Laser in situ keratomileusis to correct high myopia. J Cataract Refract Surg. 1997;23:372–385
  5. Steinert RF, Bafna S. Surgical correction of moderate myopia: which method should you choose? II. PRK and LASIK are the treatment of choice. Surv Ophthalmol. 1998;43:157–159
  6. Seiler T, Koufala K, Richter G. Iatrogenic keratectasia after laser in situ keratomileusis. J Refract Surg. 1998;14:312–317
  7. Jacobs BJ, Deutsch TA, Rubenstein JB. Reproducibility of corneal flap thickness in LASIK. Ophthalmic Surg Lasers. 1999;30:350–353
  8. Yi W-M, Joo C-K. Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome. J Cataract Refract Surg. 1999;25:1087–1092
  9. Behrens A, Langenbucher A, Kus MM, et al. Experimental evaluation of two current-generation automated microkeratomes: the Hansatome and the Supratome. Am J Ophthalmol. 2000;129:59–67
  10. Gailitis RP, Lagzdins M. Factors that affect corneal flap thickness with the Hansatome microkeratome. J Cataract Refract Surg. 2002;18:439–443
  11. Behrens A, Seitz B, Langenbucher A, et al. Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome. J Refract Surg. 2000;16:83–89
  12. Kim YH, Choi J-S, Chun HJ, Joo C-K. Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis. J Cataract Refract Surg. 1999;25:1448–1455
  13. Yildirim R, Aras C, Ozdamar A, et al. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg. 2000;26:1729–1732
  14. Maldonado MJ, Ruiz-Oblitas L, Munuera JM, et al. Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism. Ophthalmology. 2000;107:81–87discussion by DR Hardten, 88
  15. Spadea L, Cerrone L, Necozione S, Balestrazzi E. Flap measurements with the Hansatome microkeratome. J Refract Surg. 2002;18:149–154
  16. Choi YI, Park SJ, Song BJ. Corneal flap dimensions in laser in situ keratomileusis using the Innovatome automatic microkeratome. Korean J Ophthalmol. 2000;14:7–11
  17. Durairaj VD, Balentine J, Kouyoumdjian G, et al. The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis. Ophthalmology. 2000;107:2140–2143
  18. Naripthaphan P, Vongthongsri A. Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis. J Refract Surg. 2001;17:S255–S258
  19. Shemesh G, Dotan G, Lipshitz I. Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes. J Refract Surg. 2002;18:S347–S351
  20. Gokmen F, Jester JV, Petroll WM, et al. In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis. J Cataract Refract Surg. 2002;28:962–970
  21. Giledi O, Mulhern MG, Espinosa M, et al. Reproducibility of LASIK flap thickness using the Hansatome microkeratome. J Cataract Refract Surg. 2004;30:1031–1037
  22. Taneri S. Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads. J Cataract Refract Surg. 2006;32:72–77
  23. Seo KY, Wan XH, Jang JW, et al. Effect of microkeratome suction duration on corneal flap thickness and incisional angle. J Refract Surg. 2002;18:715–719
  24. Hoffmann S, Krummenauer F, Tehrani M, Dick HB. Impact of head advance and oscillation rate on the flap parameter: a comparison of two microkeratomes. Graefes Arch Clin Exp Ophthalmol. 2003;241:149–153
  25. Solomon KD, Donnenfeld E, Sandoval HP, et al. Flap thickness accuracy: comparison of 6 microkeratome models; Flap Thickness Study Group. J Cataract Refract Surg. 2004;30:964–977

 Supported in part by the Action for Vision Eye Foundation, Hong Kong, People's Republic of China.

PII: S0886-3350(07)01541-6

doi: 10.1016/j.jcrs.2007.07.027

Journal of Cataract & Refractive Surgery
Volume 33, Issue 12 , Pages 2049-2053 , December 2007