Journal of Cataract & Refractive Surgery
Volume 34, Issue 4 , Pages 557-561 , April 2008

Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis

  • Hyojin Kim, PhD
  • ,
  • Choun-Ki Joo, MD, PhD

      Affiliations

    • Corresponding Author InformationCorresponding author: Choun-Ki Joo, MD, PhD, Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, Korea Eye Tissue and Gene Bank, College of Medicine, The Catholic University of Korea, #505 Banpo-dong, Seocho-ku, Seoul, 137-040, Republic of Korea.

,Accepted 11 November 2007.

References 

  1. Bara S, Mancebo T, Moreno-Barriuso E. Positioning tolerances for phase plates compensating aberrations of human eye. Appl Opt. 2000;39:3413–3420
  2. Guirao A, Williams DR, Cox IG. Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations. J Opt Soc Am A Opt Image Sci Vis. 2001;18:1003–1015
  3. Stevens JD. Astigmatic excimer laser treatment: theoretical effects of axis misalignment. Eur J Implant Refract Surg. 1994;6:310–318
  4. Swami AU, Steinert RF, Osborne WE, White AA. Rotational malposition during laser in situ keratomileusis. Am J Ophthalmol. 2002;133:561–562
  5. Chernyak DA. Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery. J Cataract Refract Surg. 2004;30:633–638
  6. Chernyak DA. Iris-based cyclotorsional image alignment method for wavefront registration. IEEE Trans Biomed Eng. 2005;52:2032–2040
  7. Tjon-Fo-Sang MJ, de Faber J-THN, Kingma C, Beekhuis WH. Cyclotorsion: a possible cause of residual astigmatism in refractive surgery. J Cataract Refract Surg. 2002;28:599–602
  8. Smith EM, Talamo JH. Cyclotorsion in the seated and supine patient. J Cataract Refract Surg. 1995;21:402–403
  9. Clarke AH, Steineke C, Emanuel H. High image rate eye movement measurement; a novel approach using CMOS sensors and dedicated FPGA devices. In:  Lehmann T editors. Bildverarbeitung in der Medizin. Berlin, Germany: Springer Verlag; 2000;p. 398–402Available at: http://www.zmms.tu-berlin.de/de/veranstaltungen/eyes_tea/Clarke.pdfAccessed December 24, 2007
  10. Hakim OJ. Registration process key for Alcon's LADAR vision system. Rev Ophthalmol. 2002;9(August suppl: Rev Refract Surg 1:36–37). Available at: http://www.ladarvision.com/pros/library/pdf/REF621.pdfAccessed December 24, 2007
  11. Bueeler M, Mrochen M, Seiler T. Maximum permissible torsional misalignment in aberration-sensing and wavefront-guided corneal ablation. J Cataract Refract Surg. 2004;30:17–25

 Neither author has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(08)00009-6

doi: 10.1016/j.jcrs.2007.11.030

Journal of Cataract & Refractive Surgery
Volume 34, Issue 4 , Pages 557-561 , April 2008