Journal of Cataract & Refractive Surgery
Volume 34, Issue 11 , Pages 1881-1885, November 2008

Advanced personalized nomogram for myopic laser surgery: First 100 eyes

From a private practice (Lapid-Gortzak, Linden), Driebergen, and the Department of Ophthalmology (Lapid-Gortzak, van der Meulen, Nieuwendaal), Academic Medical Centre, University of Amsterdam, The Netherlands

Purpose

To report the results in the first 100 eyes treated for myopia using a new advanced nomogram.

Setting

Private refractive surgery clinic.

Methods

This prospective interventional case series comprised 58 patients (100 eyes) consecutively treated for myopia with laser in situ keratomileusis (LASIK) or laser-assisted subepithelial keratectomy (LASEK) performed by the same surgeon. All treatments used a new nomogram for the Zyoptix 217 Z100 excimer laser. Postoperative mean sphere, cylinder, and spherical equivalent (SE) refraction were evaluated 3 months postoperatively. Safety, efficacy, and predictability were also evaluated.

Results

In the LASIK group (34 eyes), the mean postoperative sphere was +0.18 diopters (D) ± 0.47 (SD), the mean postoperative cylinder was −0.10 ± 0.23 D, and the mean postoperative SE was 0.04 ± 0.36 D. In the LASEK group (64 eyes), the respective means were 0.10 ± 0.22 D, −0.05 ± 0.13 D, and +0.03 ± 0.16 D. Hyperopic overcorrection (≥+1.00 D) occurred in 4.1% of patients. Ninety-five percent of eyes in the LASIK group and 97% of eyes in the LASIK group had an uncorrected visual acuity of 1.0 (20/20) or better. Patient satisfaction was slightly higher than that of other laser refractive surgery patients at the clinic.

Conclusions

The use of the advanced nomogram increased treatment accuracy in terms of UCVA and postoperative mean refraction and reduced the rate of hyperopic overcorrection over that in earlier studies. The need for enhancement procedures was reduced, and patient satisfaction was high.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 No author has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(08)00838-9

doi:10.1016/j.jcrs.2008.06.041

Journal of Cataract & Refractive Surgery
Volume 34, Issue 11 , Pages 1881-1885, November 2008