Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2096-2098 , December 2008

Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation

,Accepted 15 August 2008.

References 

  1. Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156–162
  2. Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement; quantitative analysis. J Cataract Refract Surg. 2005;31:146–155
  3. Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143:39–47
  4. Ortiz D, Piñero D, Shabayek MH, Arnalich-Montiel F, Alió JL. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg. 2007;33:1371–1375
  5. Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the Ocular Response Analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci. 2007;48:3026–3031Available at http://www.iovs.org/cgi/reprint/48/7/3026Accessed August 23, 2008
  6. Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006;141:868–875
  7. Kirwan C, O'Keefe M. Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK. Acta Ophthalmol (Copenh). 2008;86:215–218
  8. Medeiros F, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma. 2006;15:364–370
  9. Herndon LW. Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol. 2006;17:115–119
  10. Falkenberg B, Kutschan A, Wiegand W. Analyse der optisch wirksamen Parameter nach Kataraktoperation mit Faltlinsenimplantation. [Analysis of optical parameters after cataract surgery and implantation of foldable lens.]. Ophthalmologe. 2005;102:587–591
  11. Hager A, Loge K, Füllhas M-O, Schroeder B, Groβherr M, Wiegand W. Changes in corneal hysteresis after clear corneal cataract surgery. Am J Ophthalmol. 2007;144:341–346

 No author has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(08)00861-4

doi: 10.1016/j.jcrs.2008.08.017

Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2096-2098 , December 2008