Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2110-2118, December 2008

Influence of anterior chamber morphometrics on endothelial cell changes after phakic intraocular lens implantation

From the Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands

Accepted 20 August 2008.

Purpose

To analyze the position of iris-fixated phakic intraocular lenses (pIOLs) using anterior segment optical coherence tomography (AS-OCT) and evaluate the effect of anterior chamber morphometrics on endothelial cell changes.

Setting

Department of Ophthalmology, Academic Hospital Maastricht, The Netherlands.

Methods

In this cross-sectional study, AS-OCT was used to measure the distances from the center and the edges of the pIOL to the corneal endothelium in 242 eyes with various models of myopic pIOLs. Endothelial cell measurements were performed preoperatively and at each follow-up examination.

Results

The mean follow-up was 34.1 months ± 24.7 (SD) (range 3 months to 7 years). The mean distance between the edge of the pIOL and the endothelium was 1.37 ± 0.22 mm. Although this distance was smaller than the safety value of 1.50 mm in 68.6% of the eyes, no eye developed corneal decompensation. There was a significant endothelial cell density (ECD) loss of 1.28% ± 8.46%, 3.25% ± 8.24%, and 5.02% ± 10.40% at 2 years, 5 years, and 7 years, respectively. Linear mixed-model analysis predicted a yearly ECD loss of 0.98% for a mean edge distance of 1.37 mm, 0.15% for an edge distance of 1.59 mm (mean plus 1 SD), and 1.80% for an edge distance of 1.15 mm (mean minus 1 SD).

Conclusions

A shorter distance between the edge of the pIOL and the endothelium was significantly associated with higher ECD loss. For safety reasons, the postoperative examination should include long-term evaluation of the anterior chamber morphometrics in addition to ECD counts.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 No author has a financial or proprietary interest in any material or method mentioned

PII: S0886-3350(08)00890-0

doi:10.1016/j.jcrs.2008.08.023

Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2110-2118, December 2008