Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2099-2103, December 2008

Safety of incomplete incision patterns in femtosecond laser–assisted penetrating keratoplasty

From a private practice (F.W. Price) and the Cornea Research Foundation of America (M.O. Price), Indianapolis, Indiana, and Northeastern Eye Institute (Jordan), Scranton, Pennsylvania, USA

Accepted 18 August 2008.

Purpose

To evaluate the wound integrity of incomplete contoured corneal incisions created with a femtosecond laser at a refractive surgery center followed by subsequent patient transfer to a separate surgical facility for penetrating keratoplasty (PKP).

Setting

Private tertiary referral center, Indianapolis, Indiana, USA.

Methods

This retrospective consecutive interventional case series comprised 46 eyes that had femtosecond laser PKP. Incomplete contoured incisions were created in the recipient cornea at a refractive surgery center. Patients were then transferred to an ambulatory surgical center for PKP.

Results

The indications for PKP included keratoconus, corneal scarring, bullous keratopathy, corneal dystrophy, and failed graft. Three incision contours were used: top hat (n = 26), mushroom (n = 13), and zigzag (n = 7). The incomplete portion of the incision was 70.0 to 300.0 μm in length. Leaving 150.0 to 300.0 μm of the lamellar ring cut incomplete did not ensure wound stability, whereas leaving 70.0 to 75.0 μm of the anterior side cut or posterior side cut incomplete provided excellent wound stability. In all eyes, the partial-thickness incisions enabled safe transport of the patient to the operating room without wound rupture, even with subsequent placement of a retrobulbar injection and a Honan balloon.

Conclusion

Incomplete femtosecond laser incision patterns that left some collagen lamellae intact maintained sufficient corneal strength to allow safe movement of the patient to a surgical facility for PKP.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Dr. Price is a consultant to Advanced Medical Optics. No other author has a financial or proprietary interest in any material or method mentioned.

PII: S0886-3350(08)00897-3

doi:10.1016/j.jcrs.2008.08.028

Journal of Cataract & Refractive Surgery
Volume 34, Issue 12 , Pages 2099-2103, December 2008