Journal of Cataract & Refractive Surgery
Volume 35, Issue 3 , Pages 444-450 , March 2009

In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography

Received 11 July 2008 ,Revised 5 November 2008 ,Accepted 12 November 2008.

References 

  1. Lyle WA, Jin GJC. Prospective evaluation of early visual and refractive effects with small clear corneal incision for cataract surgery. J Cataract Refract Surg. 1996;22:1456–1460
  2. Nichamin LD, Chang DF, Johnson SH, Mamalis N, Masket S, Packard RB, et al. ASCRS White Paper: What is the association between clear corneal cataract incisions and postoperative endophthalmitis?. [special report] J Cataract Refract Surg. 2006;32:1556–1559
  3. Faulkner HW. Association between clear corneal cataract incisions and postoperative endophthalmitis. [letter] J Cataract Refract Surg. 2007;33:562
  4. Masket S. Is there a relationship between clear corneal cataract incisions and endophthalmitis?. [guest editorial] J Cataract Refract Surg. 2005;31:643–345
  5. Gajjar D, Praveen MR, Vasavada AR, Pandita D, Vasavada VA, Patel DB, et al. Ingress of bacterial inoculum into the anterior chamber after bimanual and microcoaxial phacoemulsification in rabbits. J Cataract Refract Surg. 2007;33:2129–2134
  6. Taban M, Rao B, Reznik J, Zhang J, Chen Z, McDonnell PJ. Dynamic morphology of sutureless cataract wounds—effect of incision angle and location. Surv Ophthalmol. 2004;49(suppl 2):S62–S72
  7. Masket S, Belani S. Proper wound construction to prevent short-term ocular hypotony after clear corneal incision cataract surgery. J Cataract Refract Surg. 2007;33:383–386
  8. Praveen MR, Vasavada AR, Gajjar D, Pandita D, Vasavada VA, Vasavada VA, et al. Comparative quantification of ingress of trypan blue into the anterior chamber after microcoaxial, standard coaxial, and bimanual phacoemulsification; randomized clinical trial. J Cataract Refract Surg. 2008;34:1007–1012
  9. Taban M, Sarayba MA, Ignacio TS, Behrens A, McDonnell PJ. Ingress of India ink into the anterior chamber through sutureless clear corneal cataract wounds. Arch Ophthalmol. 2005;123:643–648
  10. Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, et al. Optical coherence tomography. Science. 1991;254:1178–1181
  11. Torres LF, Saez-Espinola F, Colina JM, Retchkiman M, Patel MR, Agurto R, et al. In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomography. J Cataract Refract Surg. 2006;32:1820–1826
  12. Radhakrishnan S, Rollins AM, Roth JE, Yazdanfar S, Westphal V, Bardenstein DS, et al. Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol. 2001;119:1179–1185
  13. Wirbelauer C, Karandish A, Häberle H, Pham DT. Noncontact goniometry with optical coherence tomography. Arch Ophthalmol. 2005;123:179–185
  14. Baikoff G, Lutun E, Ferraz C, Wei J. Analyse du segment antérieur de l'oeil avec un tomographe à cohérence optique. Étude statique et dynamique. [Analysis of the eye's anterior segment with optical coherence tomography. Static and dynamic study]. J Fr Ophtalmol. 2005;28:343–352
  15. Baikoff G, Jodai HJ, Bourgeon G. Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg. 2005;31:1722–1728
  16. Fine IH, Hoffman RS, Packer M. Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography. J Cataract Refract Surg. 2007;33:94–97
  17. Chylack LT, Wolfe JK, Singer DM, Leske MC, Bullimore MA, Bailey IL, et al. The Lens Opacities Classification System III; the Longitudinal Study of Cataract Study Group. Arch Ophthalmol. 1993;111:831–836
  18. Osher RH, Injev NP. Microcoaxial phacoemulsification. Part 1: laboratory studies. J Cataract Refract Surg. 2007;33:401–407
  19. Osher RH. Microcoaxial phacoemulsification. Part 2: clinical study. J Cataract Refract Surg. 2007;33:408–412
  20. Bolz M, Sacu S, Drexler W, Findl O. Local corneal thickness changes after small-incision cataract surgery. J Cataract Refract Surg. 2006;32:1667–1671
  21. Berdahl JP, DeStafeno JJ, Kim T. Corneal wound architecture and integrity after phacoemulsification; evaluation of coaxial, microincision coaxial, and microincision bimanual techniques. J Cataract Refract Surg. 2007;33:510–515
  22. Tsuneoka H, Shiba T, Takahashi Y. Feasibility of ultrasound cataract surgery with a 1.4 mm incision. J Cataract Refract Surg. 2001;27:934–940
  23. Soscia W, Howard JG, Olson RJ. Microphacoemulsification with WhiteStar; a wound-temperature study. J Cataract Refract Surg. 2002;28:1044–1046
  24. Donnenfeld ED, Olson RJ, Solomon R, Finger PT, Biser SA, Perry HD, et al. Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision. J Cataract Refract Surg. 2003;29:1097–1100
  25. Soscia W, Howard JG, Olson RJ. Bimanual phacoemulsification through 2 stab incisions; a wound-temperature study. J Cataract Refract Surg. 2002;28:1039–1043
  26. Mackool RJ. Temperature during bimanual phacoemulsification. [letter] J Cataract Refract Surg. 2004;30:732;reply by ED Donnenfeld, RJ Olson, 732–733

 No author has a financial or proprietary interest in any material or method mentioned.

 Presented in part as a poster at the annual meeting of the Association for Research in Vision and Ophthalmology, Fort Lauderdale, Florida, USA, May 2008.

 Supported by Quinze-Vingts National Ophthalmology Hospital, Paris, France.

PII: S0886-3350(08)01162-0

doi: 10.1016/j.jcrs.2008.11.034

Journal of Cataract & Refractive Surgery
Volume 35, Issue 3 , Pages 444-450 , March 2009