« Previous
Next »
Journal of Cataract & Refractive Surgery
Volume 35, Issue 7
, Pages 1266-1272
, July 2009
Analysis of intraocular lens surface adhesiveness by atomic force microscopy
References
- . Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics; randomized clinical trial. Ophthalmology. 2005;112:67–72
- . Optic edge design as long-term factor for posterior capsular opacification rates. Ophthalmology. 2008;115:1308–1314
- . Posterior capsule opacification after implantation of CeeOn Edge 911A, PhacoFlex SI-40NB, and AcrySof MA60BM lenses; one-year results of an intraindividual comparison multicenter study. J Cataract Refract Surg. 2004;30:978–985
- . Eradication of posterior capsule opacification; documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology. 2001;108:505–518
- . The effect of capsulorhexis size on posterior capsular opacification: one-year results of a randomized prospective trial. Am J Ophthalmol. 1999;128:271–279
- . Effect of anterior polishing on fibrotic capsule opacification: three-year results. J Cataract Refract Surg. 2004;30:2322–2327
- . Efficacy and safety of capsular bending ring implantation to prevent posterior capsule opacification; three-year results of a randomized clinical trial. J Cataract Refract Surg. 2008;34:1318–1328
- . Interventions for preventing posterior capsule opacification. Cochrane Database Syst Rev. 2007;(3):CD003738. Available at http://mrw.interscience.wiley.com/cochrane/clsysrev/articles/CD003738/pdf_fs.htmlAccessed February 24, 2009
- . A new model of posterior capsule opacification in rodents. Invest Ophthalmol Vis Sci. 2003;44:3450–3457Available at http://www.iovs.org/cgi/reprint/44/8/3450Accessed February 23, 2009
- . Shape of lens epithelial cells after intraocular lens implantation. J Cataract Refract Surg. 2001;27:745–752
- . Evaluation of cellular adhesions on silicone and poly(methyl methacrylate) intraocular lenses in monkey eyes; an electron microscopic study. J Cataract Refract Surg. 2001;27:2036–2040
- . Cellular reaction on the anterior surface of 4 types of intraocular lenses. J Cataract Refract Surg. 2001;27:734–740
- . Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses. J Cataract Refract Surg. 2002;28:50–61
- . Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002;28:1105–1111
- . Inhibition of lens epithelial cell migration at the intraocular lens optic edge; role of capsule bending and contact pressure. J Cataract Refract Surg. 2003;29:1605–1612
- . Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg. 2000;26:1543–1549
- . Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification. Ophthalmology. 2008;115:830–838
- . The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology. 1999;106:49–54discussion by RC Drews, 54–55
- . Posterior capsule opacification: comparison of 3 intraocular lenses of different materials and design. J Cataract Refract Surg. 2003;29:1556–1559
- . Lens epithelial cell outgrowth on 3 types of intraocular lenses. J Cataract Refract Surg. 2001;27:850–854
- . Effect of intraocular lenses on preventing posterior capsule opacification: design versus material. J Cataract Refract Surg. 2004;30:2170–2176
- . Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2003;29:348–353
- . Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses. J Cataract Refract Surg. 2002;28:431–437
- . Analysis of intraocular lens surface properties with atomic force microscopy. J Cataract Refract Surg. 2006;32:1378–1384
- . Surface roughness of intraocular lenses and inflammatory cell adhesion to lens surfaces. J Cataract Refract Surg. 2003;29:367–370
- . Force-distance curves by AFM; a powerful technique for studying surface interactions. IEEE Eng Med Biol. 1997;16(2):58–65
- . Force measurements with the atomic force microscope: technique, interpretation and applications. Surf Sci Rep. 2005;59:1–152
- . Measuring forces with the AFM: polymeric surfaces in liquids. Adv Colloid Interface Sci. 2002;99:13–75
- . Dynamic effects on force measurements. I. Viscous drag on the atomic force microscopy cantilever. Rev Sci Instrum. 2001;72:2330–2339
- . Effect of PZT and PMN actuator hysteresis and creep on nanoindentation measurements using force microscopy. Rev Sci Instrum. 1994;65:1561–1565
- . Adhesion of amorphous polymers as a function of temperature probed with AFM force-distance curves. J Colloid Interface Sci. 2006;296:507–514
- . Contact inhibition of migrating lens epithelial cells at the capsular bend created by a sharp-edged intraocular lens after cataract surgery. J Cataract Refract Surg. 2007;33:1065–1070
- . Effect of intraocular lens design on posterior capsule opacification. J Cataract Refract Surg. 2008;34:1976–1985
- . Two year results: sharp versus rounded optic edges on silicone lenses. J Cataract Refract Surg. 2000;26:566–570
- . Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics; randomized clinical trial. Ophthalmology. 2005;112:67–72
- . Influence on posterior capsule opacification and visual function of intraocular lens optic material. Am J Ophthalmol. 2007;144:195–202
- . Lens epithelial cell regression on the posterior capsule with different intraocular lens materials. Br J Ophthalmol. 1998;82:1182–1188
- . Optical coherence tomography assessment of capsule closure after cataract surgery. J Cataract Refract Surg. 2005;31:330–336
- . Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study. Br J Ophthalmol. 1998;82:549–553
- . Adherence and viability of porcine lens epithelial cells on three different IOL materials in vitro. Graefes Arch Clin Exp Ophthalmol. 2003;241:823–826
- . Inhibition of lens epithelial cell migration by an acrylic intraocular lens in vitro. Ophthalmic Res. 2002;34:29–37
- . Adhesion mechanisms of human lens epithelial cells on 4 intraocular lens materials. J Cataract Refract Surg. 1999;25:527–533
- . Intermolecular and Surface Forces, with Applications to Colloidal and Biological Systems. 2nd ed.. San Diego, CA: Academic Press; 1992;128–131
- . Posterior capsular opacification and lens epithelial cell layer formation: Hydroview hydrogel versus AcrySof acrylic intraocular lenses. J Cataract Refract Surg. 2001;27:1047–1054
- . Mathematical modeling of the forces between an intraocular lens and the capsule. J Cataract Refract Surg. 2002;28:1853–1859
- . Regional mechanical properties and stress analysis of the human anterior lens capsule. Vision Res. 2007;47:1781–1789
- . Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials. J Cataract Refract Surg. 1999;25:1486–1491
- . Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes. Part 1: histological sections. J Cataract Refract Surg. 2000;26:1792–1806
- . The relationship between the adhesion characteristics of acrylic intraocular lens materials and posterior capsule opacification. Ophthalmic Res. 2007;39:276–281
- . Probing the surface forces of monolayer films with atomic-force microscopy. Phys Rev Lett. 1990;64:1931–1934
- . Modification of the surface properties of a lens material to influence posterior capsular opacification. Clin Exp Ophthalmol. 2006;34:568–574
- . Relationship between posterior capsule opacification and intraocular lens biocompatibility. Prog Retin Eye Res. 2004;23:283–305
No author has a financial or proprietary interest in any material or method mentioned.
Presented at the annual meeting of the Association for Research in Vision and Ophthalmology, Fort Lauderdale, Florida, USA, May 2009.
Innova Technology Solutions, Chieti, Italy, provided the consumables.
PII: S0886-3350(09)00364-2
doi: 10.1016/j.jcrs.2009.02.029
© 2009 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Cataract & Refractive Surgery
Volume 35, Issue 7
, Pages 1266-1272
, July 2009