Back-calculation to model strategies for pretreatment adjustment of the ablation sphere in myopic wavefront laser in situ keratomileusis

From Moorfields Eye Hospital (Arnalich-Montiel, Wilson, Allan) and Abbott Medical Optics UK Ltd (Morton), London, United Kingdom

Received 29 October 2008; received in revised form 26 February 2009; accepted 4 March 2009.

Purpose

To examine strategies for adjusting the ablation sphere in myopic wavefront laser in situ keratomileusis (LASIK) with reference to preoperative manifest refraction.

Setting

Refractive Surgery Service, Moorfields Eye Hospital, London, United Kingdom.

Methods

The variance in the 3-month postoperative manifest refraction spherical equivalent (MRSE) results in 295 consecutive cases of myopic wavefront LASIK treated with a nonsystematic, intuitive approach to pretreatment adjustment of the ablation sphere was compared with the variance in modeled results obtained by back-calculation using 4 systematic strategies: (1) no adjustment (No Adj), (2) addition of the difference between the preoperative MRSE and the preoperative 4.0 mm pupil wavefront refraction spherical equivalent (WRSE) (4.0 mm), (3) addition of the difference between the preoperative MRSE and the preoperative maximum pupil WRSE (Max), and (4) addition of the difference between the preoperative MRSE and the preoperative effective blur (EB). The EB is a theoretical value for the dioptric SE of all aberrations at the pupil size calculated for the Hartmann-Shack images acquired (wavefront diameter). A stratified analysis of results for different wavefront diameters was also performed.

Results

Variance in the postoperative MRSE was least (0.116) when nonsystematic, intuitive adjustments to the ablation sphere were used. In ascending order, the back-calculated variance was as follows: EB (0.142; P = .09, Bartlett test), 4.0 mm pupil (0.163; P = .004), No Adj (0.171; P = .001), and Max (0.225; P<.0001). There was a strong trend toward reduced variance in results in patients with a larger wavefront diameter.

Conclusion

Back-calculation to model results with different pretreatment ablation adjustment strategies may be useful to eliminate unpromising new approaches before clinical trials.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Steven Morton is a paid employee of Abbott Medical Optics UK. No other author has a financial or proprietary interest in any material or method mentioned.

 Charlie Campbell, PhD, Abbott Medical Optics, Milpitas, California, USA, described the effective blur concept.