Journal of Cataract & Refractive Surgery
Volume 37, Issue 8 , Pages 1386-1393, August 2011

Repositioning and scleral fixation of subluxated lenses using a T-shaped capsule stabilization hook

Presented at the XXVIII Congress of the European Society of Cataract and Refractive Surgeons, Paris, France, September 2010.

From the Department of Ophthalmology (Saori Yaguchi, Negishi, Tsubota), Keio University School of Medicine, Tokyo, the Department of Ophthalmology (Shigeo Yaguchi, Asano), School of Medicine, Showa University, Fujigaoka Hospital, Yokohama, and the Kozawa Eye Hospital and Diabetes Center (Kozawa, Miyawaki), Mito, Japan

Received 16 February 2011; received in revised form 20 April 2011; accepted 5 May 2011.

We describe a T-shaped capsule stabilization hook (modified capsule expander [M-CE]) used for repositioning and scleral fixation of the lens capsule of subluxated lenses. The 5-0 polypropylene device is flexible and attached to a curved needle. The contact portion is bent at 1.25 mm, and the end bifurcates in a T configuration to form a 3.75 mm footpad from which the capsular bag can be suspended. Modified capsule expanders were implanted in 4 eyes of 4 patients with subluxated cataractous lenses and provided excellent support and centration of the intraocular lens (IOL)–capsular bag complex. The IOLs remained well centered and stable. The corrected distance visual acuity improved to at least 20/20 in all patients after surgery. Thus, M-CEs were effective in fixating the lens capsule to the sclera in patients with significant zonular weakness.

Financial Disclosure

Saori Yaguchi, Y. Asano, T. Kozawa, T. Miyawaki, K. Negishi, and K. Tsubota have no financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Additional financial disclosures: Shigeo Yaguchi is the inventor of the modified capsule expander and received financial support from Handaya Co. Ltd., Tokyo, Japan.

PII: S0886-3350(11)00883-2

doi:10.1016/j.jcrs.2011.06.015

Journal of Cataract & Refractive Surgery
Volume 37, Issue 8 , Pages 1386-1393, August 2011